Color.Spectral.Tables
(Color v0.4.0)
Copy Markdown
Standard CIE color matching functions and illuminant spectral power distributions, tabulated at 5 nm intervals from 380 nm to 780 nm (81 samples).
Sources:
CMFs — CIE 1931 2° and CIE 1964 10° standard observer colour matching functions, CIE 15:2004.
D65, D50 — CIE 15:2004 Table T.1.
Illuminant A — computed on demand from the Planckian radiator formula at
T = 2856 K(seeColor.Spectral.illuminant/1).Illuminant C, E — E is flat; C is computed from legacy tabulated values.
All values are relative; consumers should normalise by
∫ S(λ) · ȳ(λ) dλ (or the pre-computed y_integral/2 value) to get
Y = 1 at the reference white.