Grizzly.ZWave.Commands.DoorLockConfigurationSet (grizzly v0.17.3) View Source
This command is used to set the configuration parameters of a door lock device.
Params:
:operation_type- the operation type at the supporting node. One of :constant_operation and :timed_operation. (required):manual_outside_door_handles- List of outside handles (1..4) that can open locally (required):manual_inside_door_handles- List of inside handles (1..4) that can open locally (required):lock_timeout- The seconds that the supporting node must wait before returning to the securedmode when receiving timed operation modes in a Door Lock Operation Set Command (required):auto_relock_time- The time setting in seconds for auto-relock functionality. (v.4 only):hold_and_release_time- The time setting in seconds for letting the latch retracted after thesupporting node’s mode has been changed to unsecured. (v.4 only):twist_assist?- Indicates if the twist assist functionality is enabled. (v.4 only):block_to_block?- Indicates if the block-to-block functionality is enabled. (v.4 only)
Link to this section Summary
Link to this section Types
Specs
param() ::
{:operation_type, Grizzly.ZWave.CommandClasses.DoorLock.operation_type()}
| {:manual_outside_door_handles, [1..4]}
| {:manual_inside_door_handles, [1..4]}
| {:lock_timeout, non_neg_integer()}
| {:auto_relock_time, non_neg_integer()}
| {:hold_and_release_time, non_neg_integer()}
| {:twist_assist?, boolean()}
| {:block_to_block?, boolean()}