Prometheus.ex v2.0.0 Prometheus.Metric.Counter View Source
Counter is a Metric that represents a single numerical value that only ever
goes up. That implies that it cannot be used to count items whose number can
also go down, e.g. the number of currently running processes. Those
“counters” are represented by Prometheus.Metric.Gauge.
A Counter is typically used to count requests served, tasks completed, errors occurred, etc.
Example use cases for Counters:
- Number of requests processed;
- Number of items that were inserted into a queue;
- Total amount of data that a system has processed.
Use the rate()/
irate()
functions in Prometheus to calculate the rate of increase of a Counter.
By convention, the names of Counters are suffixed by _total.
To create a counter use either new/1 or declare/1, the difference is that
new/ will raise Prometheus.MFAlreadyExistsError exception if counter with
the same registry, name and labels combination already exists.
Both accept spec Keyword with the same set of keys:
:registry- optional, default is:default;:name- required, can be an atom or a string;:help- required, must be a string;:labels- optional, default is[].
Example:
defmodule MyServiceInstrumenter do
use Prometheus.Metric
## to be called at app/supervisor startup.
## to tolerate restarts use declare.
def setup() do
Counter.declare([name: :my_service_requests_total,
help: "Requests count.",
labels: [:caller]])
end
def inc(caller) do
Counter.inc([name: :my_service_requests_total,
labels: [caller]])
end
end
Link to this section Summary
Functions
Increments the counter identified by spec by 1 when body executed
Increments the counter identified by spec by 1 when body raises exception
Increments the counter identified by spec by 1 when body raises no exceptions
Creates a counter using spec.
If a counter with the same spec exists returns false
Increments the counter identified by spec by value.
If value happened to be a float number even one time(!) you
shouldn’t use inc/2 after dinc
Increments the counter identified by spec by value
Creates a counter using spec
Removes counter series identified by spec
Resets the value of the counter identified by spec
Returns the value of the counter identified by spec. If there is no counter for
given labels combination, returns :undefined
Link to this section Functions
Increments the counter identified by spec by 1 when body executed.
Read more about bodies: Prometheus.Injector.
Raises Prometheus.InvalidValueError exception if value isn’t a positive integer.
Raises Prometheus.UnknownMetricError exception if a counter
for spec can’t be found.
Raises Prometheus.InvalidMetricArityError exception if labels count mismatch.
Increments the counter identified by spec by 1 when body raises exception.
Read more about bodies: Prometheus.Injector.
Raises Prometheus.InvalidValueError exception if value isn’t a positive integer.
Raises Prometheus.UnknownMetricError exception if a counter
for spec can’t be found.
Raises Prometheus.InvalidMetricArityError exception if labels count mismatch.
Increments the counter identified by spec by 1 when body raises no exceptions.
Read more about bodies: Prometheus.Injector.
Raises Prometheus.InvalidValueError exception if value isn’t a positive integer.
Raises Prometheus.UnknownMetricError exception if a counter
for spec can’t be found.
Raises Prometheus.InvalidMetricArityError exception if labels count mismatch.
Creates a counter using spec.
If a counter with the same spec exists returns false.
Raises Prometheus.MissingMetricSpecKeyError if required spec key is missing.
Raises Prometheus.InvalidMetricNameError if metric name is invalid.
Raises Prometheus.InvalidMetricHelpError if help is invalid.
Raises Prometheus.InvalidMetricLabelsError if labels isn’t a list.
Raises Prometheus.InvalidLabelNameError if label name is invalid.
Increments the counter identified by spec by value.
If value happened to be a float number even one time(!) you
shouldn’t use inc/2 after dinc.
Raises Prometheus.InvalidValueError exception if value isn’t a positive number.
Raises Prometheus.UnknownMetricError exception if a counter
for spec can’t be found.
Raises Prometheus.InvalidMetricArityError exception if labels count mismatch.
Increments the counter identified by spec by value.
Raises Prometheus.InvalidValueError exception if value isn’t a positive integer.
Raises Prometheus.UnknownMetricError exception if a counter
for spec can’t be found.
Raises Prometheus.InvalidMetricArityError exception if labels count mismatch.
Creates a counter using spec.
Raises Prometheus.MissingMetricSpecKeyError if required spec key is missing.
Raises Prometheus.InvalidMetricNameError if metric name is invalid.
Raises Prometheus.InvalidMetricHelpError if help is invalid.
Raises Prometheus.InvalidMetricLabelsError if labels isn’t a list.
Raises Prometheus.InvalidLabelNameError if label name is invalid.
Raises Prometheus.MFAlreadyExistsError if a counter with
the same spec already exists.
Removes counter series identified by spec.
Raises Prometheus.UnknownMetricError exception if a counter
for spec can’t be found.
Raises Prometheus.InvalidMetricArityError exception if labels count mismatch.
Resets the value of the counter identified by spec.
Raises Prometheus.UnknownMetricError exception if a counter
for spec can’t be found.
Raises Prometheus.InvalidMetricArityError exception if labels count mismatch.
Returns the value of the counter identified by spec. If there is no counter for
given labels combination, returns :undefined.
Raises Prometheus.UnknownMetricError exception if a counter
for spec can’t be found.
Raises Prometheus.InvalidMetricArityError exception if labels count mismatch.